Interface CreateCollectionRequestOrBuilder

All Superinterfaces:
com.google.protobuf.MessageLiteOrBuilder, com.google.protobuf.MessageOrBuilder
All Known Implementing Classes:
CreateCollectionRequest, CreateCollectionRequest.Builder

public interface CreateCollectionRequestOrBuilder extends com.google.protobuf.MessageOrBuilder
  • Method Summary

    Modifier and Type
    Method
    Description
    Not useful for now
    Not useful for now
    The unique collection name in milvus.(Required)
    com.google.protobuf.ByteString
    The unique collection name in milvus.(Required)
    The consistency level that the collection used, modification is not supported now.
    int
    The consistency level that the collection used, modification is not supported now.
    string db_name = 2;
    com.google.protobuf.ByteString
    string db_name = 2;
    long
    num of default physical partitions, only used in partition key mode and changes are not supported
    getProperties(int index)
    repeated .milvus.proto.common.KeyValuePair properties = 7;
    int
    repeated .milvus.proto.common.KeyValuePair properties = 7;
    repeated .milvus.proto.common.KeyValuePair properties = 7;
    repeated .milvus.proto.common.KeyValuePair properties = 7;
    repeated .milvus.proto.common.KeyValuePair properties = 7;
    com.google.protobuf.ByteString
    The serialized `schema.CollectionSchema`(Required)
    int
    Once set, no modification is allowed (Optional) https://github.com/milvus-io/milvus/issues/6690
    boolean
    Not useful for now

    Methods inherited from interface com.google.protobuf.MessageLiteOrBuilder

    isInitialized

    Methods inherited from interface com.google.protobuf.MessageOrBuilder

    findInitializationErrors, getAllFields, getDefaultInstanceForType, getDescriptorForType, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof
  • Method Details

    • hasBase

      boolean hasBase()
       Not useful for now
       
      .milvus.proto.common.MsgBase base = 1;
      Returns:
      Whether the base field is set.
    • getBase

      MsgBase getBase()
       Not useful for now
       
      .milvus.proto.common.MsgBase base = 1;
      Returns:
      The base.
    • getBaseOrBuilder

      MsgBaseOrBuilder getBaseOrBuilder()
       Not useful for now
       
      .milvus.proto.common.MsgBase base = 1;
    • getDbName

      String getDbName()
      string db_name = 2;
      Returns:
      The dbName.
    • getDbNameBytes

      com.google.protobuf.ByteString getDbNameBytes()
      string db_name = 2;
      Returns:
      The bytes for dbName.
    • getCollectionName

      String getCollectionName()
       The unique collection name in milvus.(Required)
       
      string collection_name = 3;
      Returns:
      The collectionName.
    • getCollectionNameBytes

      com.google.protobuf.ByteString getCollectionNameBytes()
       The unique collection name in milvus.(Required)
       
      string collection_name = 3;
      Returns:
      The bytes for collectionName.
    • getSchema

      com.google.protobuf.ByteString getSchema()
       The serialized `schema.CollectionSchema`(Required)
       
      bytes schema = 4;
      Returns:
      The schema.
    • getShardsNum

      int getShardsNum()
       Once set, no modification is allowed (Optional)
       https://github.com/milvus-io/milvus/issues/6690
       
      int32 shards_num = 5;
      Returns:
      The shardsNum.
    • getConsistencyLevelValue

      int getConsistencyLevelValue()
       The consistency level that the collection used, modification is not supported now.
       
      .milvus.proto.common.ConsistencyLevel consistency_level = 6;
      Returns:
      The enum numeric value on the wire for consistencyLevel.
    • getConsistencyLevel

      ConsistencyLevel getConsistencyLevel()
       The consistency level that the collection used, modification is not supported now.
       
      .milvus.proto.common.ConsistencyLevel consistency_level = 6;
      Returns:
      The consistencyLevel.
    • getPropertiesList

      List<KeyValuePair> getPropertiesList()
      repeated .milvus.proto.common.KeyValuePair properties = 7;
    • getProperties

      KeyValuePair getProperties(int index)
      repeated .milvus.proto.common.KeyValuePair properties = 7;
    • getPropertiesCount

      int getPropertiesCount()
      repeated .milvus.proto.common.KeyValuePair properties = 7;
    • getPropertiesOrBuilderList

      List<? extends KeyValuePairOrBuilder> getPropertiesOrBuilderList()
      repeated .milvus.proto.common.KeyValuePair properties = 7;
    • getPropertiesOrBuilder

      KeyValuePairOrBuilder getPropertiesOrBuilder(int index)
      repeated .milvus.proto.common.KeyValuePair properties = 7;
    • getNumPartitions

      long getNumPartitions()
       num of default physical partitions, only used in partition key mode and changes are not supported
       
      int64 num_partitions = 8;
      Returns:
      The numPartitions.