public class StaticHelper
extends Object
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
|15|14|13|12|11|10| 9| 8| 7| 6| 5| 4| 3| 2| 1|
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
\__________/\__________/\____________________/
Module Number of Number of the partial
class the partial list
list
extract
Module Class:
+--------------+-----------------+
| Module class | Coding (Binary) |
+--------------|-----------------+
| CPU | 0000 |
+--------------|-----------------+
| IM | 0100 |
+--------------|-----------------+
| FM | 1000 |
+--------------|-----------------+
| CP | 1100 |
+--------------|-----------------+
Possible SSL Partial Lists:
+-----------------------------------------------------------|--------------+
| Module class | SSL-ID |
+-----------------------------------------------------------|--------------+
| Module identification | 16#xy11 |
+-----------------------------------------------------------|--------------+
| CPU characteristics | 16#xy12 |
+-----------------------------------------------------------|--------------+
| User memory areas | 16#xy13 |
+-----------------------------------------------------------|--------------+
| System areas | 16#xy14 |
+-----------------------------------------------------------|--------------+
| Block types | 16#xy15 |
+-----------------------------------------------------------|--------------+
| Interrupt status | 16#xy22 |
+-----------------------------------------------------------|--------------+
| Assignment between process image partitions and OBs | 16#xy25 |
+-----------------------------------------------------------|--------------+
| Communication status data | 16#xy32 |
+-----------------------------------------------------------|--------------+
| H CPU group information | 16#xy71 |
+-----------------------------------------------------------|--------------+
| Status of the module LEDs | 16#xy74 |
+-----------------------------------------------------------|--------------+
| Switched DP slaves in the H-system | 16#xy75 |
+-----------------------------------------------------------|--------------+
| Module status information | 16#xy91 |
+-----------------------------------------------------------|--------------+
| Rack / station status information | 16#xy92 |
+-----------------------------------------------------------|--------------+
| Rack / station status information | 16#xy94 |
+-----------------------------------------------------------|--------------+
| Extended DP master system / PROFINET IO system information| 16#xy95 |
+-----------------------------------------------------------|--------------+
| Module status information, PROFINET IO and PROFIBUS DP | 16#xy96 |
+-----------------------------------------------------------|--------------+
| Tool changer information (PROFINET IO) | 16#xy9C |
+-----------------------------------------------------------|--------------+
| Diagnostic buffer of the CPU | 16#xyA0 |
+-----------------------------------------------------------|--------------+
| Module diagnostic information (data record 0) | 16#xyB1 |
+-----------------------------------------------------------|--------------+
| Module diagnostic information (data record 1), | 16#xyB2 |
| geographical address | |
+-----------------------------------------------------------|--------------+
| Module diagnostic information (data record 1), | 16#xyB3 |
| logical address | |
+-----------------------------------------------------------|--------------+
| Diagnostic data of a DP slave | 16#xyB4 |
+-----------------------------------------------------------|--------------+