public static interface CheckpointConfiguration.Builder extends SdkPojo, CopyableBuilder<CheckpointConfiguration.Builder,CheckpointConfiguration>
| Modifier and Type | Method and Description |
|---|---|
CheckpointConfiguration.Builder |
checkpointingEnabled(Boolean checkpointingEnabled)
Describes whether checkpointing is enabled for a Flink-based Kinesis Data Analytics application.
|
CheckpointConfiguration.Builder |
checkpointInterval(Long checkpointInterval)
Describes the interval in milliseconds between checkpoint operations.
|
CheckpointConfiguration.Builder |
configurationType(ConfigurationType configurationType)
Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior.
|
CheckpointConfiguration.Builder |
configurationType(String configurationType)
Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior.
|
CheckpointConfiguration.Builder |
minPauseBetweenCheckpoints(Long minPauseBetweenCheckpoints)
Describes the minimum time in milliseconds after a checkpoint operation completes that a new checkpoint
operation can start.
|
equalsBySdkFields, sdkFieldscopyapplyMutation, buildCheckpointConfiguration.Builder configurationType(String configurationType)
Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior. You must set
this property to CUSTOM in order to set the CheckpointingEnabled,
CheckpointInterval, or MinPauseBetweenCheckpoints parameters.
If this value is set to DEFAULT, the application will use the following values, even if they are
set to other values using APIs or application code:
CheckpointingEnabled: true
CheckpointInterval: 60000
MinPauseBetweenCheckpoints: 5000
configurationType - Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior. You
must set this property to CUSTOM in order to set the CheckpointingEnabled,
CheckpointInterval, or MinPauseBetweenCheckpoints parameters.
If this value is set to DEFAULT, the application will use the following values, even if
they are set to other values using APIs or application code:
CheckpointingEnabled: true
CheckpointInterval: 60000
MinPauseBetweenCheckpoints: 5000
ConfigurationType,
ConfigurationTypeCheckpointConfiguration.Builder configurationType(ConfigurationType configurationType)
Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior. You must set
this property to CUSTOM in order to set the CheckpointingEnabled,
CheckpointInterval, or MinPauseBetweenCheckpoints parameters.
If this value is set to DEFAULT, the application will use the following values, even if they are
set to other values using APIs or application code:
CheckpointingEnabled: true
CheckpointInterval: 60000
MinPauseBetweenCheckpoints: 5000
configurationType - Describes whether the application uses Kinesis Data Analytics' default checkpointing behavior. You
must set this property to CUSTOM in order to set the CheckpointingEnabled,
CheckpointInterval, or MinPauseBetweenCheckpoints parameters.
If this value is set to DEFAULT, the application will use the following values, even if
they are set to other values using APIs or application code:
CheckpointingEnabled: true
CheckpointInterval: 60000
MinPauseBetweenCheckpoints: 5000
ConfigurationType,
ConfigurationTypeCheckpointConfiguration.Builder checkpointingEnabled(Boolean checkpointingEnabled)
Describes whether checkpointing is enabled for a Flink-based Kinesis Data Analytics application.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application will use a
CheckpointingEnabled value of true, even if this value is set to another value
using this API or in application code.
checkpointingEnabled - Describes whether checkpointing is enabled for a Flink-based Kinesis Data Analytics application.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application
will use a CheckpointingEnabled value of true, even if this value is set to
another value using this API or in application code.
CheckpointConfiguration.Builder checkpointInterval(Long checkpointInterval)
Describes the interval in milliseconds between checkpoint operations.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application will use a
CheckpointInterval value of 60000, even if this value is set to another value using this API or
in application code.
checkpointInterval - Describes the interval in milliseconds between checkpoint operations.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application
will use a CheckpointInterval value of 60000, even if this value is set to another value
using this API or in application code.
CheckpointConfiguration.Builder minPauseBetweenCheckpoints(Long minPauseBetweenCheckpoints)
Describes the minimum time in milliseconds after a checkpoint operation completes that a new checkpoint
operation can start. If a checkpoint operation takes longer than the CheckpointInterval, the
application otherwise performs continual checkpoint operations. For more information, see Tuning Checkpointing in the Apache Flink Documentation.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application will use a
MinPauseBetweenCheckpoints value of 5000, even if this value is set using this API or in
application code.
minPauseBetweenCheckpoints - Describes the minimum time in milliseconds after a checkpoint operation completes that a new
checkpoint operation can start. If a checkpoint operation takes longer than the
CheckpointInterval, the application otherwise performs continual checkpoint operations.
For more information, see Tuning Checkpointing in the Apache Flink
Documentation.
If CheckpointConfiguration.ConfigurationType is DEFAULT, the application
will use a MinPauseBetweenCheckpoints value of 5000, even if this value is set using this
API or in application code.
Copyright © 2022. All rights reserved.