public static interface PutParameterRequest.Builder extends SsmRequest.Builder, SdkPojo, CopyableBuilder<PutParameterRequest.Builder,PutParameterRequest>
| Modifier and Type | Method and Description |
|---|---|
PutParameterRequest.Builder |
allowedPattern(String allowedPattern)
A regular expression used to validate the parameter value.
|
PutParameterRequest.Builder |
dataType(String dataType)
The data type for a
String parameter. |
PutParameterRequest.Builder |
description(String description)
Information about the parameter that you want to add to the system.
|
PutParameterRequest.Builder |
keyId(String keyId)
The Key Management Service (KMS) ID that you want to use to encrypt a parameter.
|
PutParameterRequest.Builder |
name(String name)
The fully qualified name of the parameter that you want to add to the system.
|
PutParameterRequest.Builder |
overrideConfiguration(AwsRequestOverrideConfiguration overrideConfiguration) |
PutParameterRequest.Builder |
overrideConfiguration(Consumer<AwsRequestOverrideConfiguration.Builder> builderConsumer) |
PutParameterRequest.Builder |
overwrite(Boolean overwrite)
Overwrite an existing parameter.
|
PutParameterRequest.Builder |
policies(String policies)
One or more policies to apply to a parameter.
|
PutParameterRequest.Builder |
tags(Collection<Tag> tags)
Optional metadata that you assign to a resource.
|
PutParameterRequest.Builder |
tags(Consumer<Tag.Builder>... tags)
Optional metadata that you assign to a resource.
|
PutParameterRequest.Builder |
tags(Tag... tags)
Optional metadata that you assign to a resource.
|
PutParameterRequest.Builder |
tier(ParameterTier tier)
The parameter tier to assign to a parameter.
|
PutParameterRequest.Builder |
tier(String tier)
The parameter tier to assign to a parameter.
|
PutParameterRequest.Builder |
type(ParameterType type)
The type of parameter that you want to add to the system.
|
PutParameterRequest.Builder |
type(String type)
The type of parameter that you want to add to the system.
|
PutParameterRequest.Builder |
value(String value)
The parameter value that you want to add to the system.
|
buildoverrideConfigurationequalsBySdkFields, sdkFieldscopyapplyMutation, buildPutParameterRequest.Builder name(String name)
The fully qualified name of the parameter that you want to add to the system. The fully qualified name
includes the complete hierarchy of the parameter path and name. For parameters in a hierarchy, you must
include a leading forward slash character (/) when you create or reference a parameter. For example:
/Dev/DBServer/MySQL/db-string13
Naming Constraints:
Parameter names are case sensitive.
A parameter name must be unique within an Amazon Web Services Region
A parameter name can't be prefixed with "aws" or "ssm" (case-insensitive).
Parameter names can include only the following symbols and letters: a-zA-Z0-9_.-
In addition, the slash character ( / ) is used to delineate hierarchies in parameter names. For example:
/Dev/Production/East/Project-ABC/MyParameter
A parameter name can't include spaces.
Parameter hierarchies are limited to a maximum depth of fifteen levels.
For additional information about valid values for parameter names, see Creating Systems Manager parameters in the Amazon Web Services Systems Manager User Guide.
The maximum length constraint listed below includes capacity for additional system attributes that aren't part of the name. The maximum length for a parameter name, including the full length of the parameter ARN, is 1011 characters. For example, the length of the following parameter name is 65 characters, not 20 characters:
arn:aws:ssm:us-east-2:111122223333:parameter/ExampleParameterName
name - The fully qualified name of the parameter that you want to add to the system. The fully qualified name
includes the complete hierarchy of the parameter path and name. For parameters in a hierarchy, you
must include a leading forward slash character (/) when you create or reference a parameter. For
example: /Dev/DBServer/MySQL/db-string13
Naming Constraints:
Parameter names are case sensitive.
A parameter name must be unique within an Amazon Web Services Region
A parameter name can't be prefixed with "aws" or "ssm" (case-insensitive).
Parameter names can include only the following symbols and letters: a-zA-Z0-9_.-
In addition, the slash character ( / ) is used to delineate hierarchies in parameter names. For
example: /Dev/Production/East/Project-ABC/MyParameter
A parameter name can't include spaces.
Parameter hierarchies are limited to a maximum depth of fifteen levels.
For additional information about valid values for parameter names, see Creating Systems Manager parameters in the Amazon Web Services Systems Manager User Guide.
The maximum length constraint listed below includes capacity for additional system attributes that aren't part of the name. The maximum length for a parameter name, including the full length of the parameter ARN, is 1011 characters. For example, the length of the following parameter name is 65 characters, not 20 characters:
arn:aws:ssm:us-east-2:111122223333:parameter/ExampleParameterName
PutParameterRequest.Builder description(String description)
Information about the parameter that you want to add to the system. Optional but recommended.
Don't enter personally identifiable information in this field.
description - Information about the parameter that you want to add to the system. Optional but recommended.
Don't enter personally identifiable information in this field.
PutParameterRequest.Builder value(String value)
The parameter value that you want to add to the system. Standard parameters have a value limit of 4 KB. Advanced parameters have a value limit of 8 KB.
Parameters can't be referenced or nested in the values of other parameters. You can't include
{{}} or {{ssm:parameter-name}} in a parameter value.
value - The parameter value that you want to add to the system. Standard parameters have a value limit of 4
KB. Advanced parameters have a value limit of 8 KB.
Parameters can't be referenced or nested in the values of other parameters. You can't include
{{}} or {{ssm:parameter-name}} in a parameter value.
PutParameterRequest.Builder type(String type)
The type of parameter that you want to add to the system.
SecureString isn't currently supported for CloudFormation templates.
Items in a StringList must be separated by a comma (,). You can't use other punctuation or
special character to escape items in the list. If you have a parameter value that requires a comma, then use
the String data type.
Specifying a parameter type isn't required when updating a parameter. You must specify a parameter type when creating a parameter.
type - The type of parameter that you want to add to the system.
SecureString isn't currently supported for CloudFormation templates.
Items in a StringList must be separated by a comma (,). You can't use other punctuation
or special character to escape items in the list. If you have a parameter value that requires a comma,
then use the String data type.
Specifying a parameter type isn't required when updating a parameter. You must specify a parameter type when creating a parameter.
ParameterType,
ParameterTypePutParameterRequest.Builder type(ParameterType type)
The type of parameter that you want to add to the system.
SecureString isn't currently supported for CloudFormation templates.
Items in a StringList must be separated by a comma (,). You can't use other punctuation or
special character to escape items in the list. If you have a parameter value that requires a comma, then use
the String data type.
Specifying a parameter type isn't required when updating a parameter. You must specify a parameter type when creating a parameter.
type - The type of parameter that you want to add to the system.
SecureString isn't currently supported for CloudFormation templates.
Items in a StringList must be separated by a comma (,). You can't use other punctuation
or special character to escape items in the list. If you have a parameter value that requires a comma,
then use the String data type.
Specifying a parameter type isn't required when updating a parameter. You must specify a parameter type when creating a parameter.
ParameterType,
ParameterTypePutParameterRequest.Builder keyId(String keyId)
The Key Management Service (KMS) ID that you want to use to encrypt a parameter. Either the default KMS key
automatically assigned to your Amazon Web Services account or a custom key. Required for parameters that use
the SecureString data type.
If you don't specify a key ID, the system uses the default key associated with your Amazon Web Services account.
To use your default KMS key, choose the SecureString data type, and do not specify the
Key ID when you create the parameter. The system automatically populates Key ID
with your default KMS key.
To use a custom KMS key, choose the SecureString data type with the Key ID
parameter.
keyId - The Key Management Service (KMS) ID that you want to use to encrypt a parameter. Either the default
KMS key automatically assigned to your Amazon Web Services account or a custom key. Required for
parameters that use the SecureString data type.
If you don't specify a key ID, the system uses the default key associated with your Amazon Web Services account.
To use your default KMS key, choose the SecureString data type, and do not specify
the Key ID when you create the parameter. The system automatically populates
Key ID with your default KMS key.
To use a custom KMS key, choose the SecureString data type with the Key ID
parameter.
PutParameterRequest.Builder overwrite(Boolean overwrite)
Overwrite an existing parameter. The default value is false.
overwrite - Overwrite an existing parameter. The default value is false.PutParameterRequest.Builder allowedPattern(String allowedPattern)
A regular expression used to validate the parameter value. For example, for String types with values restricted to numbers, you can specify the following: AllowedPattern=^\d+$
allowedPattern - A regular expression used to validate the parameter value. For example, for String types with values
restricted to numbers, you can specify the following: AllowedPattern=^\d+$PutParameterRequest.Builder tags(Collection<Tag> tags)
Optional metadata that you assign to a resource. Tags enable you to categorize a resource in different ways, such as by purpose, owner, or environment. For example, you might want to tag a Systems Manager parameter to identify the type of resource to which it applies, the environment, or the type of configuration data referenced by the parameter. In this case, you could specify the following key-value pairs:
Key=Resource,Value=S3bucket
Key=OS,Value=Windows
Key=ParameterType,Value=LicenseKey
To add tags to an existing Systems Manager parameter, use the AddTagsToResource operation.
tags - Optional metadata that you assign to a resource. Tags enable you to categorize a resource in different
ways, such as by purpose, owner, or environment. For example, you might want to tag a Systems Manager
parameter to identify the type of resource to which it applies, the environment, or the type of
configuration data referenced by the parameter. In this case, you could specify the following
key-value pairs:
Key=Resource,Value=S3bucket
Key=OS,Value=Windows
Key=ParameterType,Value=LicenseKey
To add tags to an existing Systems Manager parameter, use the AddTagsToResource operation.
PutParameterRequest.Builder tags(Tag... tags)
Optional metadata that you assign to a resource. Tags enable you to categorize a resource in different ways, such as by purpose, owner, or environment. For example, you might want to tag a Systems Manager parameter to identify the type of resource to which it applies, the environment, or the type of configuration data referenced by the parameter. In this case, you could specify the following key-value pairs:
Key=Resource,Value=S3bucket
Key=OS,Value=Windows
Key=ParameterType,Value=LicenseKey
To add tags to an existing Systems Manager parameter, use the AddTagsToResource operation.
tags - Optional metadata that you assign to a resource. Tags enable you to categorize a resource in different
ways, such as by purpose, owner, or environment. For example, you might want to tag a Systems Manager
parameter to identify the type of resource to which it applies, the environment, or the type of
configuration data referenced by the parameter. In this case, you could specify the following
key-value pairs:
Key=Resource,Value=S3bucket
Key=OS,Value=Windows
Key=ParameterType,Value=LicenseKey
To add tags to an existing Systems Manager parameter, use the AddTagsToResource operation.
PutParameterRequest.Builder tags(Consumer<Tag.Builder>... tags)
Optional metadata that you assign to a resource. Tags enable you to categorize a resource in different ways, such as by purpose, owner, or environment. For example, you might want to tag a Systems Manager parameter to identify the type of resource to which it applies, the environment, or the type of configuration data referenced by the parameter. In this case, you could specify the following key-value pairs:
Key=Resource,Value=S3bucket
Key=OS,Value=Windows
Key=ParameterType,Value=LicenseKey
To add tags to an existing Systems Manager parameter, use the AddTagsToResource operation.
List.Builder avoiding the need to
create one manually via List#builder() .
When the Consumer completes, List.Builder#build() is called immediately and its result
is passed to #tags(List) .tags - a consumer that will call methods on List.Builder #tags(List) PutParameterRequest.Builder tier(String tier)
The parameter tier to assign to a parameter.
Parameter Store offers a standard tier and an advanced tier for parameters. Standard parameters have a content size limit of 4 KB and can't be configured to use parameter policies. You can create a maximum of 10,000 standard parameters for each Region in an Amazon Web Services account. Standard parameters are offered at no additional cost.
Advanced parameters have a content size limit of 8 KB and can be configured to use parameter policies. You can create a maximum of 100,000 advanced parameters for each Region in an Amazon Web Services account. Advanced parameters incur a charge. For more information, see Standard and advanced parameter tiers in the Amazon Web Services Systems Manager User Guide.
You can change a standard parameter to an advanced parameter any time. But you can't revert an advanced parameter to a standard parameter. Reverting an advanced parameter to a standard parameter would result in data loss because the system would truncate the size of the parameter from 8 KB to 4 KB. Reverting would also remove any policies attached to the parameter. Lastly, advanced parameters use a different form of encryption than standard parameters.
If you no longer need an advanced parameter, or if you no longer want to incur charges for an advanced parameter, you must delete it and recreate it as a new standard parameter.
Using the Default Tier Configuration
In PutParameter requests, you can specify the tier to create the parameter in. Whenever you
specify a tier in the request, Parameter Store creates or updates the parameter according to that request.
However, if you don't specify a tier in a request, Parameter Store assigns the tier based on the current
Parameter Store default tier configuration.
The default tier when you begin using Parameter Store is the standard-parameter tier. If you use the advanced-parameter tier, you can specify one of the following as the default:
Advanced: With this option, Parameter Store evaluates all requests as advanced parameters.
Intelligent-Tiering: With this option, Parameter Store evaluates each request to determine if the parameter is standard or advanced.
If the request doesn't include any options that require an advanced parameter, the parameter is created in the standard-parameter tier. If one or more options requiring an advanced parameter are included in the request, Parameter Store create a parameter in the advanced-parameter tier.
This approach helps control your parameter-related costs by always creating standard parameters unless an advanced parameter is necessary.
Options that require an advanced parameter include the following:
The content size of the parameter is more than 4 KB.
The parameter uses a parameter policy.
More than 10,000 parameters already exist in your Amazon Web Services account in the current Amazon Web Services Region.
For more information about configuring the default tier option, see Specifying a default parameter tier in the Amazon Web Services Systems Manager User Guide.
tier - The parameter tier to assign to a parameter.
Parameter Store offers a standard tier and an advanced tier for parameters. Standard parameters have a content size limit of 4 KB and can't be configured to use parameter policies. You can create a maximum of 10,000 standard parameters for each Region in an Amazon Web Services account. Standard parameters are offered at no additional cost.
Advanced parameters have a content size limit of 8 KB and can be configured to use parameter policies. You can create a maximum of 100,000 advanced parameters for each Region in an Amazon Web Services account. Advanced parameters incur a charge. For more information, see Standard and advanced parameter tiers in the Amazon Web Services Systems Manager User Guide.
You can change a standard parameter to an advanced parameter any time. But you can't revert an advanced parameter to a standard parameter. Reverting an advanced parameter to a standard parameter would result in data loss because the system would truncate the size of the parameter from 8 KB to 4 KB. Reverting would also remove any policies attached to the parameter. Lastly, advanced parameters use a different form of encryption than standard parameters.
If you no longer need an advanced parameter, or if you no longer want to incur charges for an advanced parameter, you must delete it and recreate it as a new standard parameter.
Using the Default Tier Configuration
In PutParameter requests, you can specify the tier to create the parameter in. Whenever
you specify a tier in the request, Parameter Store creates or updates the parameter according to that
request. However, if you don't specify a tier in a request, Parameter Store assigns the tier based on
the current Parameter Store default tier configuration.
The default tier when you begin using Parameter Store is the standard-parameter tier. If you use the advanced-parameter tier, you can specify one of the following as the default:
Advanced: With this option, Parameter Store evaluates all requests as advanced parameters.
Intelligent-Tiering: With this option, Parameter Store evaluates each request to determine if the parameter is standard or advanced.
If the request doesn't include any options that require an advanced parameter, the parameter is created in the standard-parameter tier. If one or more options requiring an advanced parameter are included in the request, Parameter Store create a parameter in the advanced-parameter tier.
This approach helps control your parameter-related costs by always creating standard parameters unless an advanced parameter is necessary.
Options that require an advanced parameter include the following:
The content size of the parameter is more than 4 KB.
The parameter uses a parameter policy.
More than 10,000 parameters already exist in your Amazon Web Services account in the current Amazon Web Services Region.
For more information about configuring the default tier option, see Specifying a default parameter tier in the Amazon Web Services Systems Manager User Guide.
ParameterTier,
ParameterTierPutParameterRequest.Builder tier(ParameterTier tier)
The parameter tier to assign to a parameter.
Parameter Store offers a standard tier and an advanced tier for parameters. Standard parameters have a content size limit of 4 KB and can't be configured to use parameter policies. You can create a maximum of 10,000 standard parameters for each Region in an Amazon Web Services account. Standard parameters are offered at no additional cost.
Advanced parameters have a content size limit of 8 KB and can be configured to use parameter policies. You can create a maximum of 100,000 advanced parameters for each Region in an Amazon Web Services account. Advanced parameters incur a charge. For more information, see Standard and advanced parameter tiers in the Amazon Web Services Systems Manager User Guide.
You can change a standard parameter to an advanced parameter any time. But you can't revert an advanced parameter to a standard parameter. Reverting an advanced parameter to a standard parameter would result in data loss because the system would truncate the size of the parameter from 8 KB to 4 KB. Reverting would also remove any policies attached to the parameter. Lastly, advanced parameters use a different form of encryption than standard parameters.
If you no longer need an advanced parameter, or if you no longer want to incur charges for an advanced parameter, you must delete it and recreate it as a new standard parameter.
Using the Default Tier Configuration
In PutParameter requests, you can specify the tier to create the parameter in. Whenever you
specify a tier in the request, Parameter Store creates or updates the parameter according to that request.
However, if you don't specify a tier in a request, Parameter Store assigns the tier based on the current
Parameter Store default tier configuration.
The default tier when you begin using Parameter Store is the standard-parameter tier. If you use the advanced-parameter tier, you can specify one of the following as the default:
Advanced: With this option, Parameter Store evaluates all requests as advanced parameters.
Intelligent-Tiering: With this option, Parameter Store evaluates each request to determine if the parameter is standard or advanced.
If the request doesn't include any options that require an advanced parameter, the parameter is created in the standard-parameter tier. If one or more options requiring an advanced parameter are included in the request, Parameter Store create a parameter in the advanced-parameter tier.
This approach helps control your parameter-related costs by always creating standard parameters unless an advanced parameter is necessary.
Options that require an advanced parameter include the following:
The content size of the parameter is more than 4 KB.
The parameter uses a parameter policy.
More than 10,000 parameters already exist in your Amazon Web Services account in the current Amazon Web Services Region.
For more information about configuring the default tier option, see Specifying a default parameter tier in the Amazon Web Services Systems Manager User Guide.
tier - The parameter tier to assign to a parameter.
Parameter Store offers a standard tier and an advanced tier for parameters. Standard parameters have a content size limit of 4 KB and can't be configured to use parameter policies. You can create a maximum of 10,000 standard parameters for each Region in an Amazon Web Services account. Standard parameters are offered at no additional cost.
Advanced parameters have a content size limit of 8 KB and can be configured to use parameter policies. You can create a maximum of 100,000 advanced parameters for each Region in an Amazon Web Services account. Advanced parameters incur a charge. For more information, see Standard and advanced parameter tiers in the Amazon Web Services Systems Manager User Guide.
You can change a standard parameter to an advanced parameter any time. But you can't revert an advanced parameter to a standard parameter. Reverting an advanced parameter to a standard parameter would result in data loss because the system would truncate the size of the parameter from 8 KB to 4 KB. Reverting would also remove any policies attached to the parameter. Lastly, advanced parameters use a different form of encryption than standard parameters.
If you no longer need an advanced parameter, or if you no longer want to incur charges for an advanced parameter, you must delete it and recreate it as a new standard parameter.
Using the Default Tier Configuration
In PutParameter requests, you can specify the tier to create the parameter in. Whenever
you specify a tier in the request, Parameter Store creates or updates the parameter according to that
request. However, if you don't specify a tier in a request, Parameter Store assigns the tier based on
the current Parameter Store default tier configuration.
The default tier when you begin using Parameter Store is the standard-parameter tier. If you use the advanced-parameter tier, you can specify one of the following as the default:
Advanced: With this option, Parameter Store evaluates all requests as advanced parameters.
Intelligent-Tiering: With this option, Parameter Store evaluates each request to determine if the parameter is standard or advanced.
If the request doesn't include any options that require an advanced parameter, the parameter is created in the standard-parameter tier. If one or more options requiring an advanced parameter are included in the request, Parameter Store create a parameter in the advanced-parameter tier.
This approach helps control your parameter-related costs by always creating standard parameters unless an advanced parameter is necessary.
Options that require an advanced parameter include the following:
The content size of the parameter is more than 4 KB.
The parameter uses a parameter policy.
More than 10,000 parameters already exist in your Amazon Web Services account in the current Amazon Web Services Region.
For more information about configuring the default tier option, see Specifying a default parameter tier in the Amazon Web Services Systems Manager User Guide.
ParameterTier,
ParameterTierPutParameterRequest.Builder policies(String policies)
One or more policies to apply to a parameter. This operation takes a JSON array. Parameter Store, a capability of Amazon Web Services Systems Manager supports the following policy types:
Expiration: This policy deletes the parameter after it expires. When you create the policy, you specify the expiration date. You can update the expiration date and time by updating the policy. Updating the parameter doesn't affect the expiration date and time. When the expiration time is reached, Parameter Store deletes the parameter.
ExpirationNotification: This policy initiates an event in Amazon CloudWatch Events that notifies you about the expiration. By using this policy, you can receive notification before or after the expiration time is reached, in units of days or hours.
NoChangeNotification: This policy initiates a CloudWatch Events event if a parameter hasn't been modified for a specified period of time. This policy type is useful when, for example, a secret needs to be changed within a period of time, but it hasn't been changed.
All existing policies are preserved until you send new policies or an empty policy. For more information about parameter policies, see Assigning parameter policies.
policies - One or more policies to apply to a parameter. This operation takes a JSON array. Parameter Store, a
capability of Amazon Web Services Systems Manager supports the following policy types:
Expiration: This policy deletes the parameter after it expires. When you create the policy, you specify the expiration date. You can update the expiration date and time by updating the policy. Updating the parameter doesn't affect the expiration date and time. When the expiration time is reached, Parameter Store deletes the parameter.
ExpirationNotification: This policy initiates an event in Amazon CloudWatch Events that notifies you about the expiration. By using this policy, you can receive notification before or after the expiration time is reached, in units of days or hours.
NoChangeNotification: This policy initiates a CloudWatch Events event if a parameter hasn't been modified for a specified period of time. This policy type is useful when, for example, a secret needs to be changed within a period of time, but it hasn't been changed.
All existing policies are preserved until you send new policies or an empty policy. For more information about parameter policies, see Assigning parameter policies.
PutParameterRequest.Builder dataType(String dataType)
The data type for a String parameter. Supported data types include plain text and Amazon Machine
Image (AMI) IDs.
The following data type values are supported.
text
aws:ec2:image
aws:ssm:integration
When you create a String parameter and specify aws:ec2:image, Amazon Web Services
Systems Manager validates the parameter value is in the required format, such as
ami-12345abcdeEXAMPLE, and that the specified AMI is available in your Amazon Web Services
account. For more information, see Native
parameter support for Amazon Machine Image (AMI) IDs in the Amazon Web Services Systems Manager User
Guide.
dataType - The data type for a String parameter. Supported data types include plain text and Amazon
Machine Image (AMI) IDs.
The following data type values are supported.
text
aws:ec2:image
aws:ssm:integration
When you create a String parameter and specify aws:ec2:image, Amazon Web
Services Systems Manager validates the parameter value is in the required format, such as
ami-12345abcdeEXAMPLE, and that the specified AMI is available in your Amazon Web
Services account. For more information, see Native parameter support for Amazon Machine Image (AMI) IDs in the Amazon Web Services Systems
Manager User Guide.
PutParameterRequest.Builder overrideConfiguration(AwsRequestOverrideConfiguration overrideConfiguration)
overrideConfiguration in interface AwsRequest.BuilderPutParameterRequest.Builder overrideConfiguration(Consumer<AwsRequestOverrideConfiguration.Builder> builderConsumer)
overrideConfiguration in interface AwsRequest.BuilderCopyright © 2022. All rights reserved.